Class A2 FR Aluminum Composite Panel
Technical Parameters
|
No.
|
Name
|
Standard index
|
Test result
|
Single item
determination
|
1
|
Core components
|
New fire-retardant natural inorganic mineral material
|
2
|
Core density
|
1.75*103kg/m3
|
3
|
Core thickness
|
2-5mm
|
4
|
Core width
|
900-2000mm
|
5
|
Calorific value(MJ/kg)
|
≤3
|
2.3-2.4
|
pass
|
6
|
Smoke production within 600s
|
≤50
|
≤48
|
S1
|
7
|
Flaming droplets
|
No flaming droplets
|
pass
|
d 0
|
8
|
Toxicity. grade
|
Class ZA1
|
pass
|
t 0
|
9
|
Peel strength
|
≥7N/mm
|
ASTM D 903
|
pass
|
10
|
Heat performance
|
5.79Btu/hr.ft 2.0 F
(32.9W/m2.0k)
|
ASTM C518
|
pass
|
11
|
Tensile strength
|
≥40Mpa
|
ASTM E8
|
pass
|
12
|
Yield strength
|
≥30Mpa
|
ASTM E8
|
pass
|
13
|
Elongation
|
≥3%
|
ASTM E8
|
pass
|
14
|
DTUL
|
211 ℃
|
ASTM D 648
|
pass
|
15
|
Tensile strength
|
≥130N/MM2
|
EN 485-2/ASTM E8
|
pass
|
16
|
Yield strength
|
≥90N/MM2
|
EN 485-2/ASTM E8
|
pass
|
17
|
Elongation
|
≥5%
|
EN 485-2/ASTM E8
|
pass
|
18
|
Limiting oxygen index (LOI)
|
≥32
|
IS: 13501
|
pass
|
19
|
Toxicity
|
≤1
|
NCD-1409
|
pass
|
20
|
Heat release rate(HRR)
|
R1(HL3) 50KW/M2
|
ISO 5660-1
|
pass
|
21
|
Tolerance range of
panel specification
|
Thickness:±0.20mm
|
Width:+2.0mm
|
Width:+2.0mm
|
Pass the standard of EN13501-1:2007+Al:2009 by Intertek, also pass the test of SGS, BV, etc.
|